Fluke 9170, 9171, 9172, & 9173 Metrology Well Calibrators

Accurate enough for lab use, and rugged and portable enough to take anywhere
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world
• Immersion depth to 203 mm (8 in)
• Optional ITS-90 reference input reads PRTs to ±0.006 °C
• Temperature range from –45 °C to 700 °C

Every once in a while, a new product comes around that changes the rules. It happened when we introduced handheld dry-wells. It happened when we introduced Micro-Baths. Now we’ve combined bath-level performance with dry-well functionality and legitimate reference thermometry to create Metrology Wells.

With groundbreaking new proprietary electronics from Fluke Calibration's (patents pending), Metrology Wells let you bring lab-quality performance into whatever field environment you might work in. New analog and digital control techniques provide stability as good as ±0.005 °C. And with dual-zone control, axial (or “vertical") uniformity is as good as ±0.02 °C over a 60 mm (2.36 in) zone. (That’s 60 mm!) Such performance doesn’t exist anywhere else outside of fluid baths.

In short, there are six critical components of performance in an industrial heat source (which the European metrology community explains, for example, in the document EA-10/13): calibrated display accuracy, stability, axial (vertical) uniformity, radial (well-to-well) uniformity, impact from loading, and hysteresis. We added a seventh in the form of a legitimate reference thermometer input and created an entirely new product category: Metrology Wells.

(By the way, Metrology Wells are the only products on the market supported by published specifications addressing every performance category in the EA-10/13. Our specs aren’t just hopes or guidelines. They apply to every Metrology Well we sell.)
Download
Produk Lainnya
Fluke 9150 Thermocouple Furnace
Fluke 9150 Thermocouple Furnace
Low cost thermocouple furnace
• Low-cost thermocouple furnace
• NIST-traceable calibration included
• RS-232 port standard

You told us you weren’t satisfied with the competition’s furnaces for checking industrial thermocouples. You said you wanted something new and more convenient to use—and you wanted it at a lower price than any other furnace available. Well, we’ve got what you asked for, and it’s the Model 9150 Thermocouple Furnace.
Fluke 9101 ZeroPoint DryWell
Fluke 9101 Zero-Point Dry-Well
Ice-point reference without the ice
• Bath-quality stability in a portable ice-point reference
• Easy re-calibration for long-term reliability
• Ready-light frees user’s time and attention
• Solid-state cooling technology

Have you been thinking about buying a zero-point dry-well? Forget those ugly-looking units the competition makes. You can get a great looking and great performing zero-point dry-well from Fluke Calibration.

The 9101 has three test wells for inserting more than one probe at a time. All three wells are stable to ±0.005 °C. One well accommodates changeable inserts for varying probe diameters.
Fluke 9190A UltraCool Field Metrology Well
Fluke 9190A Ultra-Cool Field Metrology Well
Key features
Ultra-cool dry-block calibrator with best-in-class stability

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market. It’s ideal for applications that demand strict quality control and regulatory process compliance. These applications include on-location validation and calibration of RTDs, thermocouples, thermometers, and sensors used with process control equipment such as medical freezers, laboratory refrigerators, cold rooms, blood banks, sterilizers (autoclaves), and freeze dryers.

Wide temperature range
–95 °C to 140 °C

Excellent accuracy
Accuracy using built-in referencethermometer readout: ±0.05 °C full range
Display accuracy: ±0.2 °C full range
Best-in-class stability
±0.015 °C full range

Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes

Portability
Weighs only 16 kg (35 lbs)
Built-in front and back handlesfor easy two-handed carry
Best measurement practices
Conforms with EURAMET cg-13 guidance on measurement practices for temperature calibrators
Fluke 9132 and 9133 Portable Infrared Calibrators
Fluke 9132 and 9133 Portable Infrared Calibrators
Precision when you need it for infrared temperature calibration

Fluke 9132 and Fluke 9133 Portable Infrared Calibrators features:
• Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design in a blackbody calibrator

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C.

These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact temperature measurement.