Fluke 6102, 7102, 7103 Micro-Bath Thermometer Calibrators

Portable and extremely stable
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.015 °C
• Ranges from –30 °C to 200 °C

Need portability and extreme stability? Fluke 6102, Fluke 7102, and Fluke 7103 Micro-Baths have both. We invented the Micro-Bath. And, while many have tried to duplicate it, none of them use proprietary Fluke Calibration controllers, so none of them deliver performance like a Fluke Calibration bath. Micro-Baths can be used anywhere for any type of sensor. The 6102 weighs less than 4.5 kg (10 lb.), with the fluid. It’s lighter and smaller than most dry-wells, has a spill-proof lid, and is easier to carry than your lunch. You can take it where you need to go without carts or excessive effort. Micro-Baths can even be transported with the fluid in them.
Download
Produk Lainnya
Fluke 9118A Thermocouple Calibration Furnace
Fluke 9118A Thermocouple Calibration Furnace
High performance furnace for thermocouple calibrations to 1200 °C

The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics. The 9118A is the most accurate, reliable, and flexible furnace in its class, meeting the demanding requirements of high-temperature thermocouple calibration.
Fluke 700PTP1 Pneumatic Test Pump
Fluke 700PTP-1 Pneumatic Test Pump
The Fluke-700PTP-1 pneumatic test pump is capable of supplying pressures up to 600 psi, 40 bar.
For use with 700 series pressure modules or test gauges. Can be directly connected to the reference port consolidating two separate pieces when performing pressure calibration and testing. Can also be used with 717 pressure calibrators. Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar.

Fitur utama
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
o 1/4 in NPT female fitting for the reference gauge or pressure module
o 1/8 F-NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke
• Vacuum range from -12.7 psi or -.87 bar, pressure range up to 600 psi or 41 bar
Fluke 700HTP2 Hydraulic Test Pump
Fluke 700HTP-2 Hydraulic Test Pump
The Fluke 700HTP-2 is a hand operated hydraulic pressure pump designed to generate calibration pressures up to 10,000 psi/690 bar. Designed for use with Fluke-700 series high pressure modules such as the Fluke-700P09, 700P29, 700P30 and 700P31.
Ideal for calibration when connected to a Fluke high pressure module via the reference port. The 700HTP-2 uses distilled water or mineral-based hydraulic oil as a source for calibration of high pressure input devices such as pressure transmitters or pressure gauges. Can also be used with Fluke 717 pressure calibrators.

Fitur utama
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Compatible with optional Fluke-700PRV pressure relief valve designed to protect pressure modules from overpressure damage
• Improved priming
• Improved stroke limiting mechanism
Note: The user must provide a hose with appropriate end fittings to apply pressure from the UUT port to the calibration unit under test such as the Fluke-700HTH-1 hose kit
Fluke Calibration P5514B Hydraulic Pressure Comparator
Fluke Calibration P5514B Hydraulic Pressure Comparator
The P5514B Hydraulic Pressure Comparator is a simple, robust and economical pressure comparison test pump for calibrating gauges, switches and transducers with precise, fine adjust capabilities. It generates pressure to 10 000 psi (70 MPa), with a new Vernier fine-adjustment control that enables cardinal point calibrations. The P5514B can be mounted easily on a bench or used in mobile applications. Its robust design, with improved reservoir valve sealing, makes it a more stable pressure generator than previous versions of this model. Test port connections include adapters for common sizes of NPT and BSP. Connections are tool free, no sealing tape required, another design improvement which, coupled with the new Vernier fine adjustment control, simplifies and improves pressure testing.
About pressure comparison test pumps

A pressure comparison test pump or pressure comparator supplies the same precisely controlled pressure to both a reference gauge and device under test for calibration. Fluke Calibration hydraulic test pumps are used for checking pressure measuring instruments against master test gauges, indicators or transducers. These cost-effective instruments, which include several features from our popular line of hydraulic deadweight testers, are capable of easily generating high pressures and often include a Vernier for precise control for important calibration requirements.
Make it a pressure calibrator

The Fluke Calibration P5514B Hydraulic Comparison Test Pump, when combined with the 2700G Reference Pressure Gauges, becomes an easy-to-use alternative to traditional deadweight testers that covers a wide range of workload. For convenience, the P5514B is bundled together with selected 2700G Reference Pressure Gauges for a complete bench top pressure calibration solution. These pressure calibrators provide the accuracy, reliability, and capability you need to calibrate dial gauges, digital test gauges and pressure transmitters.
For example, the P5514B-2700G-3 is a P5514B comparison test pump, bundled together with 2700G-G70M, 2700G-G20M, 2700G-BG7M. This calibrator has three pressure ranges corresponding to the three 2700G Reference Pressure Gauges in the bundle and covers a total pressure range of –12 psi to 10 000 psi (–80 kPa to 70 MPa).

Key Features
• Easily generate pressure to 10 000 psi (70 MPa)
• Vernier fine adjustment control
• Tool-free test connectors for easy, leak free connections
• Test port connectors include adaptors for common sizes of NPT and BSP
• Robust design with improved reservoir valve sealing
Logo Header  Footer
Instagram
Facebook
Linkedin
Kantor Pusat
Jl.Wijaya Kusuma Raya Blok C10 No 10, Bekasi Jaya Indah (BJI) Danita, Bekasi 17112 - Indonesia
(021) 2908-5810
office@nrs.co.id
Copyright © 2026 PT Narmada Setia. All Rights Reserved
Whatsapp Detail Produk