a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
08111333128
Calibrator

Fluke 9118A Thermocouple Calibration Furnace

High performance furnace for thermocouple calibrations to 1200 °C

The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics. The 9118A is the most accurate, reliable, and flexible furnace in its class, meeting the demanding requirements of high-temperature thermocouple calibration.
Download
Produk Lainnya
Fluke 700LTP1 Lowpressure Test Pump
Fluke 700LTP-1 Low-pressure Test Pump
The Fluke 700LTP-1 is a hand operated pressure pump designed to generate either vacuum to -12.7 PSI / -.87 bar or pressures to 100 psi / 6.9 bar. The Fluke 700LTP-1 has two pressure ports with quick fit connectors. Test hoses are terminated with 1/8-NPT female fittings that can be adapted using the BSP/ISO adapters.
For use with 700 series pressure modules and 717 pressure calibrators. Ideal for low pressure applications requiring accurate low pressure testing.

Fitur utama
• Pump can be easily cleaned without disassembly
• Adjustable pressure relief valve with slow-bleed capability. Allows the slow release pressure at a controlled rate
• Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
• Slim design, easy to carry and use
Fluke 9103 9140 DryWell Calibrators  Dry Block Calibrators
Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators
Great performance in portable instruments
• Lightweight and very portable
• Accuracy to ±0.25 °C
• RS-232 interface
• Easy to recalibrate

If you’ve been using a dry well calibrator or dry block calibrator for field work, you know there’s a lot more to them than temperature range and stability. Size, weight, speed, convenience, and software are also significant.

A field dry well needs to be portable, flexible, and suitable for high-volume calibrations or certifications. If it's not, you’ll soon forget about the great stuff the sales rep told you and realize what you’ve really bought.

At Fluke Calibration, we use dry well calibrators every day in our manufacturing and calibration work, and we know what makes a dry well easy and productive to use—which is exactly how users describe our series of field dry wells. These dry wells work for you instead of the other way around.
Fluke 9009 Industrial DualBlock Thermometer Calibrator
Fluke 9009 Industrial Dual-Block Thermometer Calibrator
Double your productivity or cut your calibration time in half
• Temperatures from –15 °C to 350 °C in one unit
• Two wells in each block for simultaneous comparison calibrations
• Rugged, lightweight, water-resistant enclosure

You’ve been asking for it and now we’re making it for you. The Model 9009 Industrial Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time. Double your productivity or cut your calibration time in half—either way you look at it, your in-field temperature calibrations just got easier.
Fluke Calibration 6531 6532 EDWT Electronic Deadweight Tester Kits
Fluke Calibration 6531, 6532 E-DWT Electronic Deadweight Tester Kits
Fluke Calibration electronic deadweight tester kits feature E-DWT-H configurations combined with the accessories needed for a complete calibration system. Model 6531 options feature E-DWT-H configurations with a single quartz reference pressure transducer (Q-RPT) to offer percent of reading performance from 10 % to 100 % of device full scale. Model 6532 options feature an additional Q-RPT to maximize workload coverage, with percent of reading performance from 1 % to 100 % of device full scale. An included vacuum fill kit allows the E-DWT to be filled with your choice of compatible fluid, while eliminating problematic air pockets from the test circuit. Also included is a test station adapter to mount just about any pressure device to be tested without using PTFE tape or wrenches. 6531 and 6532 kits provide all you need to perform high level hydraulic pressure calibration right out of the box.
• Pressure ranges available to 200 MPa (30,000 psi)
• ± 0.02 % of reading total one-year accuracy, 0.025 % for two years
• Low torque variable volume allows for pressure generation and control up to 200 MPa (30,000 psi) with minimal physical effort
• Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation
• Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5
• Compatible with a wide range of liquids, including water. Vacuum fill kit included to fill the E-DWT with any compatible test medium
• AutoTest™, AutoRange, ready/not ready indicator, onboard data capture and storage, overpressure alarm, RS-232 remote interface and other advanced features to simplify testing, improve safety and prevent calibration errors and damage to equipment
• Optional foot switch accessory allows hands-free data collection when running AutoTests
• Rechargeable battery pack and transport case options for field operation

Key Features
• Eliminates the need for weights and piston-cylinder changes.
• Real-time pressure indication without need for corrections.
• Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
• Offers ± 0.02% of reading total one-year measurement uncertainty.
Logo Header  Footer
Instagram
Facebook
Linkedin
Kantor Pusat
Jl.Wijaya Kusuma Raya Blok C10 No 10, Bekasi Jaya Indah (BJI) Danita, Bekasi 17112 - Indonesia
(021) 2908-5810
office@nrs.co.id
Copyright © 2026 PT Narmada Setia. All Rights Reserved
Whatsapp Detail Produk