a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
08111333128
Calibrator

Fluke 724 Temperature Calibrator

Key features
• Powerful, easy-to-use, high-accuracy temperature calibrator
• Test and calibrate temperature sensors and transmitters
• Measures 4 to 20 mA loops and can provide loop power
• Measures RTDs, thermocouples, ohms, and volts
• Source/simulates thermocouples, RTDs, volts, and ohms
Download
Produk Lainnya
Fluke 9190A UltraCool Field Metrology Well
Fluke 9190A Ultra-Cool Field Metrology Well
Key features
Ultra-cool dry-block calibrator with best-in-class stability

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market. It’s ideal for applications that demand strict quality control and regulatory process compliance. These applications include on-location validation and calibration of RTDs, thermocouples, thermometers, and sensors used with process control equipment such as medical freezers, laboratory refrigerators, cold rooms, blood banks, sterilizers (autoclaves), and freeze dryers.

Wide temperature range
–95 °C to 140 °C

Excellent accuracy
Accuracy using built-in referencethermometer readout: ±0.05 °C full range
Display accuracy: ±0.2 °C full range
Best-in-class stability
±0.015 °C full range

Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes

Portability
Weighs only 16 kg (35 lbs)
Built-in front and back handlesfor easy two-handed carry
Best measurement practices
Conforms with EURAMET cg-13 guidance on measurement practices for temperature calibrators
Fluke Calibration 1620A Precision ThermoHygrometer
Fluke Calibration 1620A Precision Thermo-Hygrometer
Product overview: Fluke Calibration 1620A Precision Thermo-Hygrometer
Accuracy
The standard-accuracy sensor (“S” model) reads temperature to ±0.25 °C over its calibrated range of 15 °C to 35 °C. Relative humidity readings are to ±2% RH from 20% RH to 70% RH.
All DewK sensors come with accredited certificates of calibration for both temperature and humidity, complete with data and NIST traceability.
Ethernet and wireless capability
With its built-in Ethernet RJ45 jack, multiple DewKs can be monitored from the same screen using Log Ware III client-server software. Ethernet also gives you the possibility for remote connectivity over the internet, so you can monitor critical conditions while you’re away.
Cables running along the floor can be a safety hazard, and cables hanging from the ceiling and walls are an eyesore. With the DewK, simply connect your computer through an RF modem up to 100 ft away, without the clutter of all the extra cables.
If you need a printout, send data to a printer through the RS-232 interface in real time.
Math and statistical functions
In addition to temperature and humidity, the DewK calculates dew point, heat index, and rates of change for both temperature and humidity. Min, max, and a variety of other statistics are also calculated and can be shown on-screen. Daily summary statistics, including min, max, and maximum rates of change are stored for the most recent sixty days.
Calibrated sensors
With inputs for two sensors, each measuring both temperature and relative humidity, one DewK can monitor two locations at the same time. Both sensors can be run via extension cables to remote locations up to 100 feet away, or one sensor can be directly mounted to the top of the DewK.
Each sensor is calibrated for both temperature and humidity by Fluke Calibration. The calibration constants assigned to the sensors reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably between different DewKs, and the recalibration of sensors doesn’t require an accompanying DewK.
Sensors may also be assigned a unique identifier (up to 16 characters) to facilitate record keeping by matching the sensor identifier with the collected data. Each DewK ships with one sensor, with additional sensors available directly from your local Fluke Calibration sales representative, or directly from Fluke Calibration. Spare sensors may also be purchased from Fluke Calibration as a kit, which includes a case for the sensor, a wall mounting bracket, and a 25-foot extension cable.
Memory
The DewK has enough on-board memory to store up to 400,000 date- and times stamped data points. That’s two years' worth of data for both measurements from two sensors if readings are taken every ten minutes!
Alarms and battery backup
Alarm settings can be set up quickly in the DewK based on temperature, the rate of change in temperature, RH, the rate of change in RH, and instrument fault conditions. Alarms can be both visual (flashing display) and audible (beeping). Likewise, alarm settings can be set up and events triggered in Log Ware III. The DewK is also equipped with a 0 to 12 volt alarm output that can trigger a process control system.
A backup battery shuts down the DewK’s display but maintains measurements for up to 16 hours in the event of a power failure.
Large, easy-to-read display
Want to view data from across the room? Want to view data from two temperature and two humidity inputs simultaneously? Want to view data graphically, statistically, or both? At the same time?! The DewK does everything you could want—or at least everything we could think of. Up to sixteen different display setups can be stored and recalled at the touch of a single button. And all 16 can be easily modified, so you get exactly what you want.

Key Features
• Highly accurate thermo hygrometer and humidity monitor.
• Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
• Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
• Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.
• Ttwo interchangeable calibrated sensors, a large memory capacity, and upgraded software.
Fluke Calibration P3100 Hydraulic Deadweight Testers
Fluke Calibration P3100 Hydraulic Deadweight Testers
The P3100 models are available in single or dual piston format. Unit can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Operating principle
Deadweight testers are the high performance pressure standards for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.
Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.
Piston/cylinder assemblies
The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.
Weight masses
Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction
Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.

Key features
• Pressure ranges to 60,000 psi (4000 bar)
• 0.015% of reading accuracy standard (0.008% optional)
• Single or dual piston format
• Built-in hand pumps standard
• Mounted spirit level with adjustable feet
• Units can be trimmed to local gravity FOC
Fluke Calibration 6109A  7109A Portable Calibration Baths
Fluke Calibration 6109A / 7109A Portable Calibration Baths
Key features
• Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy.
• Covers a wide temperature range: 6109A: 35 °C to 250 °C
• 7109A: -25 °C to 140 °C.
• Stainless steel casing that withstands harsh cleaning solutions; it's easy to transport and maintain.