a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
08111333128
Calibrator

Fluke 4180, 4181 Precision Infrared Calibrators

Accuracy and traceability for infrared measurements

Now it’s easy to increase your IR temperature measurement accuracy with the new 4180, 4181 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

New accredited performance for point-and-shoot calibrations
• Calibrated radiometrically for meaningful, consistent results.
• Accredited calibration included
• Accurate, reliable performance from –15 °C to 500 °C
• Large target size of 152 mm (6 in) is required for calibrating most thermometers.
• Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
• Intuitive, easy-to-read display that indicates when temperature is stable.
Download
Produk Lainnya
Fluke 700PTP1 Pneumatic Test Pump
Fluke 700PTP-1 Pneumatic Test Pump
The Fluke-700PTP-1 pneumatic test pump is capable of supplying pressures up to 600 psi, 40 bar.
For use with 700 series pressure modules or test gauges. Can be directly connected to the reference port consolidating two separate pieces when performing pressure calibration and testing. Can also be used with 717 pressure calibrators. Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar.

Fitur utama
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
o 1/4 in NPT female fitting for the reference gauge or pressure module
o 1/8 F-NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke
• Vacuum range from -12.7 psi or -.87 bar, pressure range up to 600 psi or 41 bar
Fluke Calibration P5515 Comparison Test Pump
Fluke Calibration P5515 Comparison Test Pump
These instruments are used for checking pressure measuring instruments against master test gauges, indicators or transducers. These hydraulic test pumps provide a quick and easy solution for checking pressure measuring instruments to 20,000 psi (1400 bar). Designed for operation with a wide range of fluids the 5515 include several features from our popular line of deadweight testers.
• Generates pressures to 20,000 psi (1400 bar)
• Operational with a wide range of fluids
• Built-in hand pump for system priming and large volume applications
• High quality screw press for fine pressure control
• Acrylic reservoir for visibility of fluid level and quality
• Portable

Key Features
• Generates pressures to 20,000 psi (1400 bar)
• Operational with a wide range of fluids
• Built-in hand pump for system priming and large volume applications
• High quality screw press for fine pressure control
• Acrylic reservoir for visibility of fluid level and quality
• Portable
Fluke 730LTP40K
Fluke 730LTP/40K
The New Fluke 730 series portable pumps feature fast pressure generation,stable pressure and easy-to-use. These pumps can provide stable,reliable pressure during calibration. The unique design of these pumps enables them to solve the common problems of pressure pump, such as blocking, leakage and laborious operation. They are your right-hand assistant in the process of manual pressure calibration.
In conjunction with Fluke 730G Smart Digital Pressure Calibrator with internal HART communication, these test pumps enable high-efficiency and high-accuracy measurement and calibration of pressure gauges,pressure switches, pressure transmitters, which make them ideal for metrology institutes and enterprises to establish pressure laboratories.
Key features
• Pressure range -40 kPa to 40 kPa
• Ultra-precision fine adjustment, the minimum controllable adjustment granularity is high
• Special insulation, greatly reducing the influence of external temperature
• Two-year warranty. No worry to use.
• Special surface treatment, scratch and corrosion resistance.
• M20×1.5 female thread quick connection fitting.
Fluke 9103 9140 DryWell Calibrators  Dry Block Calibrators
Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators
Great performance in portable instruments
• Lightweight and very portable
• Accuracy to ±0.25 °C
• RS-232 interface
• Easy to recalibrate

If you’ve been using a dry well calibrator or dry block calibrator for field work, you know there’s a lot more to them than temperature range and stability. Size, weight, speed, convenience, and software are also significant.

A field dry well needs to be portable, flexible, and suitable for high-volume calibrations or certifications. If it's not, you’ll soon forget about the great stuff the sales rep told you and realize what you’ve really bought.

At Fluke Calibration, we use dry well calibrators every day in our manufacturing and calibration work, and we know what makes a dry well easy and productive to use—which is exactly how users describe our series of field dry wells. These dry wells work for you instead of the other way around.
Logo Header  Footer
Instagram
Facebook
Linkedin
Kantor Pusat
Jl.Wijaya Kusuma Raya Blok C10 No 10, Bekasi Jaya Indah (BJI) Danita, Bekasi 17112 - Indonesia
(021) 2908-5810
office@nrs.co.id
Copyright © 2026 PT Narmada Setia. All Rights Reserved
Whatsapp Detail Produk