Fluke 700PTP1 Pneumatic Test Pump
Fluke 700PTP-1 Pneumatic Test Pump
The Fluke-700PTP-1 pneumatic test pump is capable of supplying pressures up to 600 psi, 40 bar.
For use with 700 series pressure modules or test gauges. Can be directly connected to the reference port consolidating two separate pieces when performing pressure calibration and testing. Can also be used with 717 pressure calibrators. Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar.

Fitur utama
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
o 1/4 in NPT female fitting for the reference gauge or pressure module
o 1/8 F-NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke
• Vacuum range from -12.7 psi or -.87 bar, pressure range up to 600 psi or 41 bar
Fluke 700LTP1 Lowpressure Test Pump
Fluke 700LTP-1 Low-pressure Test Pump
The Fluke 700LTP-1 is a hand operated pressure pump designed to generate either vacuum to -12.7 PSI / -.87 bar or pressures to 100 psi / 6.9 bar. The Fluke 700LTP-1 has two pressure ports with quick fit connectors. Test hoses are terminated with 1/8-NPT female fittings that can be adapted using the BSP/ISO adapters.
For use with 700 series pressure modules and 717 pressure calibrators. Ideal for low pressure applications requiring accurate low pressure testing.

Fitur utama
• Pump can be easily cleaned without disassembly
• Adjustable pressure relief valve with slow-bleed capability. Allows the slow release pressure at a controlled rate
• Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
• Slim design, easy to carry and use
Fluke 700HTP2 Hydraulic Test Pump
Fluke 700HTP-2 Hydraulic Test Pump
The Fluke 700HTP-2 is a hand operated hydraulic pressure pump designed to generate calibration pressures up to 10,000 psi/690 bar. Designed for use with Fluke-700 series high pressure modules such as the Fluke-700P09, 700P29, 700P30 and 700P31.
Ideal for calibration when connected to a Fluke high pressure module via the reference port. The 700HTP-2 uses distilled water or mineral-based hydraulic oil as a source for calibration of high pressure input devices such as pressure transmitters or pressure gauges. Can also be used with Fluke 717 pressure calibrators.

Fitur utama
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Compatible with optional Fluke-700PRV pressure relief valve designed to protect pressure modules from overpressure damage
• Improved priming
• Improved stroke limiting mechanism
Note: The user must provide a hose with appropriate end fittings to apply pressure from the UUT port to the calibration unit under test such as the Fluke-700HTH-1 hose kit
Fluke 700 PMP Pressure Pump
Fluke 700 PMP Pressure Pump
Product review : Fluke 700 PMP Pressure Pump
Description: The Fluke 700PMP is a hand-operated pressure pump to provide pressures up to 150 psi/1000 kPa. Output fitting is 1/8 FNPT.
Application: Linear stroke of 4 cm. Multi-turn vernier for fine adjustment of pressure.
Fluke 730LTP40K
Fluke 730LTP/40K
The New Fluke 730 series portable pumps feature fast pressure generation,stable pressure and easy-to-use. These pumps can provide stable,reliable pressure during calibration. The unique design of these pumps enables them to solve the common problems of pressure pump, such as blocking, leakage and laborious operation. They are your right-hand assistant in the process of manual pressure calibration.
In conjunction with Fluke 730G Smart Digital Pressure Calibrator with internal HART communication, these test pumps enable high-efficiency and high-accuracy measurement and calibration of pressure gauges,pressure switches, pressure transmitters, which make them ideal for metrology institutes and enterprises to establish pressure laboratories.
Key features
• Pressure range -40 kPa to 40 kPa
• Ultra-precision fine adjustment, the minimum controllable adjustment granularity is high
• Special insulation, greatly reducing the influence of external temperature
• Two-year warranty. No worry to use.
• Special surface treatment, scratch and corrosion resistance.
• M20×1.5 female thread quick connection fitting.
Fluke 730LTP600K
Fluke 730LTP/600K
The New Fluke 730 series portable pumps feature fast pressure generation, stable pressure and easy-to-use. These pumps can provide stable, reliable pressure during calibration. The unique design of these pumps enables them to solve the common problems of pressure pump, such as blocking, leakage and laborious operation. They are your right-hand assistant in the process of manual pressure calibration.
In conjunction with Fluke 730G Smart Digital Pressure Calibrator with internal HART communication, these test pumps enable high-efficiency and high-accuracy measurement and calibration of pressure gauges, pressure switches, pressure transmitters, which make them ideal for metrology institutes and enterprises to establish pressure laboratories.

Key features
• Pressure range -95kPa to 600kPa
• Pressure is generated by the combination of the pressure rod and screw for faster and smoother pressure increase and decrease
• Safely switch between pressure and vacuum
• Two-year warranty. No worry to use.
• Special surface treatment, scratch and corrosion resistance.
• M20×1.5 female thread quick connection fitting
Fluke 730HTP70M
Fluke 730HTP/70M
The New Fluke 730 series portable pumps feature fast pressure generation,stable pressure and easy-to-use. These pumps can provide stable,reliable pressure during calibration. The unique design of these pumps enables them to solve the common problems of pressure pump, such as blocking, leakage and laborious operation. They are your right-hand assistant in the process of manual pressure calibration.
In conjunction with Fluke 730G Smart Digital Pressure Calibrator with internal HART communication, these test pumps enable high-efficiency and high-accuracy measurement and calibration of pressure gauges, pressure switches, pressure transmitters, which make them ideal for metrology institutes and enterprises to establish pressure laboratories.

Key features
• Pressure range 0 kPa to 70 Mpa
• The pressure generation by the pressure rod can calibrate pressure meters with a large cavity;
• fine adjustment by the screw has the high minimum controllable adjustment granularity
• Two-year warranty. No worry to use.
• Special surface treatment, scratch and corrosion resistance.
• M20×1.5 female thread quick connection fitting.
Fluke Calibration 1620A Precision ThermoHygrometer
Fluke Calibration 1620A Precision Thermo-Hygrometer
Product overview: Fluke Calibration 1620A Precision Thermo-Hygrometer
Accuracy
The standard-accuracy sensor (“S” model) reads temperature to ±0.25 °C over its calibrated range of 15 °C to 35 °C. Relative humidity readings are to ±2% RH from 20% RH to 70% RH.
All DewK sensors come with accredited certificates of calibration for both temperature and humidity, complete with data and NIST traceability.
Ethernet and wireless capability
With its built-in Ethernet RJ45 jack, multiple DewKs can be monitored from the same screen using Log Ware III client-server software. Ethernet also gives you the possibility for remote connectivity over the internet, so you can monitor critical conditions while you’re away.
Cables running along the floor can be a safety hazard, and cables hanging from the ceiling and walls are an eyesore. With the DewK, simply connect your computer through an RF modem up to 100 ft away, without the clutter of all the extra cables.
If you need a printout, send data to a printer through the RS-232 interface in real time.
Math and statistical functions
In addition to temperature and humidity, the DewK calculates dew point, heat index, and rates of change for both temperature and humidity. Min, max, and a variety of other statistics are also calculated and can be shown on-screen. Daily summary statistics, including min, max, and maximum rates of change are stored for the most recent sixty days.
Calibrated sensors
With inputs for two sensors, each measuring both temperature and relative humidity, one DewK can monitor two locations at the same time. Both sensors can be run via extension cables to remote locations up to 100 feet away, or one sensor can be directly mounted to the top of the DewK.
Each sensor is calibrated for both temperature and humidity by Fluke Calibration. The calibration constants assigned to the sensors reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably between different DewKs, and the recalibration of sensors doesn’t require an accompanying DewK.
Sensors may also be assigned a unique identifier (up to 16 characters) to facilitate record keeping by matching the sensor identifier with the collected data. Each DewK ships with one sensor, with additional sensors available directly from your local Fluke Calibration sales representative, or directly from Fluke Calibration. Spare sensors may also be purchased from Fluke Calibration as a kit, which includes a case for the sensor, a wall mounting bracket, and a 25-foot extension cable.
Memory
The DewK has enough on-board memory to store up to 400,000 date- and times stamped data points. That’s two years' worth of data for both measurements from two sensors if readings are taken every ten minutes!
Alarms and battery backup
Alarm settings can be set up quickly in the DewK based on temperature, the rate of change in temperature, RH, the rate of change in RH, and instrument fault conditions. Alarms can be both visual (flashing display) and audible (beeping). Likewise, alarm settings can be set up and events triggered in Log Ware III. The DewK is also equipped with a 0 to 12 volt alarm output that can trigger a process control system.
A backup battery shuts down the DewK’s display but maintains measurements for up to 16 hours in the event of a power failure.
Large, easy-to-read display
Want to view data from across the room? Want to view data from two temperature and two humidity inputs simultaneously? Want to view data graphically, statistically, or both? At the same time?! The DewK does everything you could want—or at least everything we could think of. Up to sixteen different display setups can be stored and recalled at the touch of a single button. And all 16 can be easily modified, so you get exactly what you want.

Key Features
• Highly accurate thermo hygrometer and humidity monitor.
• Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
• Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
• Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.
• Ttwo interchangeable calibrated sensors, a large memory capacity, and upgraded software.
Fluke Calibration P3100 Hydraulic Deadweight Testers
Fluke Calibration P3100 Hydraulic Deadweight Testers
The P3100 models are available in single or dual piston format. Unit can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Operating principle
Deadweight testers are the high performance pressure standards for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.
Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.
Piston/cylinder assemblies
The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.
Weight masses
Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction
Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.

Key features
• Pressure ranges to 60,000 psi (4000 bar)
• 0.015% of reading accuracy standard (0.008% optional)
• Single or dual piston format
• Built-in hand pumps standard
• Mounted spirit level with adjustable feet
• Units can be trimmed to local gravity FOC
Fluke Calibration P3200 Hydraulic Deadweight Tester
Fluke Calibration P3200 Hydraulic Deadweight Tester
The P3200 models are available in single or dual piston formats for increased operating ranges. Units can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Options
PressCal software for pressure calculations and certificate generation
Operating principle
Deadweight testers are the high performance pressure standard for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.
Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.

Piston/cylinder assemblies

The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.

Weight masses

Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction

Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.

Key features
• Pressure ranges to 10,000 psi (700 bar)
• 0.015% of reading accuracy standard (0.008% optional)
• Single or dual piston formats
• Built-in hand pumps standard
• Mounted spirit level with adjustable feet
• Units can be trimmed to local gravity FOC
Fluke Calibration P3000 Pneumatic Deadweight Testers
Fluke Calibration P3000 Pneumatic Deadweight Testers
This versatile instrument provides calibrations from 1-30 inHg vacuum (0.03-1 bar) and 3-500 psi (0.2-35 bar) in one extremely accurate yet easy to use primary standard. A selector valve converts the unit from pressure to vacuum mode without the need to exchange pistons. Units are manufactured to the highest standards with certified accuracies traceable to International Standards Laboratories such as the National Institute of Standards and Technology (NIST). These piston/cylinder type pneumatic standards provide excellent stability, repeatability and accuracy. An optional built-in hand pump can be added for both pressure and vacuum generation.

Key features
• 0.015% of reading accuracy standard (0.008% optional)
• 1-30 inHg vacuum (0.03-1 bar vacuum)
• 3-500 psi (0.2-35 bar) pressure
• inH2O and mbar ranges available
• Series 3 non-magnetic stainless steel weights
• Units can be trimmed to local gravity FOC
Fluke Calibration P5514B Hydraulic Pressure Comparator
Fluke Calibration P5514B Hydraulic Pressure Comparator
The P5514B Hydraulic Pressure Comparator is a simple, robust and economical pressure comparison test pump for calibrating gauges, switches and transducers with precise, fine adjust capabilities. It generates pressure to 10 000 psi (70 MPa), with a new Vernier fine-adjustment control that enables cardinal point calibrations. The P5514B can be mounted easily on a bench or used in mobile applications. Its robust design, with improved reservoir valve sealing, makes it a more stable pressure generator than previous versions of this model. Test port connections include adapters for common sizes of NPT and BSP. Connections are tool free, no sealing tape required, another design improvement which, coupled with the new Vernier fine adjustment control, simplifies and improves pressure testing.
About pressure comparison test pumps

A pressure comparison test pump or pressure comparator supplies the same precisely controlled pressure to both a reference gauge and device under test for calibration. Fluke Calibration hydraulic test pumps are used for checking pressure measuring instruments against master test gauges, indicators or transducers. These cost-effective instruments, which include several features from our popular line of hydraulic deadweight testers, are capable of easily generating high pressures and often include a Vernier for precise control for important calibration requirements.
Make it a pressure calibrator

The Fluke Calibration P5514B Hydraulic Comparison Test Pump, when combined with the 2700G Reference Pressure Gauges, becomes an easy-to-use alternative to traditional deadweight testers that covers a wide range of workload. For convenience, the P5514B is bundled together with selected 2700G Reference Pressure Gauges for a complete bench top pressure calibration solution. These pressure calibrators provide the accuracy, reliability, and capability you need to calibrate dial gauges, digital test gauges and pressure transmitters.
For example, the P5514B-2700G-3 is a P5514B comparison test pump, bundled together with 2700G-G70M, 2700G-G20M, 2700G-BG7M. This calibrator has three pressure ranges corresponding to the three 2700G Reference Pressure Gauges in the bundle and covers a total pressure range of –12 psi to 10 000 psi (–80 kPa to 70 MPa).

Key Features
• Easily generate pressure to 10 000 psi (70 MPa)
• Vernier fine adjustment control
• Tool-free test connectors for easy, leak free connections
• Test port connectors include adaptors for common sizes of NPT and BSP
• Robust design with improved reservoir valve sealing